This DDF enables the integration of the Alfen Eve Single Pro-line into the E-Mobility system.
The Alfen Eve Single Pro-line is a smart AC charging station for residential and commercial use. It supports charging power of up to 22 kW and is available depending on the model with a Type 2 socket or a fixed charging cable.
Requirements
The following requirements must be met to use this DDF:
- a compatible Alfen Eve Single Pro-line
- a functioning connection between the charging station and the E-Mobility system
- a properly configured charging station
Configuration of the Charging Station
The following settings must be configured on the charging station for integration with the E-Mobility system:
- enable Active Load Balancing
- select Energy Management System as the data source
- select either RFID or Plug+Charge to start the charging session
Usage
After successful setup, the charging station can be monitored and controlled via the DDF.
- Charging session control: Charging sessions can be started, stopped or paused via the E-Mobility system.
- Dynamic charging power: The charging power can be dynamically adjusted according to the available power.
- Renewable energy: The charging power can be adjusted according to the current generation of renewable energy.
- Grid capacity: The available grid capacity can be taken into account when controlling the charging power.
- User preferences: Corresponding user preferences can be taken into account when controlling the charging power.
Important Notes
Phase switching is currently not supported by this DDF.
RFID functionality is currently not supported by this DDF. The selection of RFID on the charging station is used for authentication and starting the charging session and is independent of DDF control.
General Info
| Manufacturer | Type | Protocol | Model | Version | ID |
|---|---|---|---|---|---|
| Alfen | Wallbox | MODBUS TCP (DDF) | 1 | 7.3.0-4377 | 0x0A00006B00010100 |
Documents
DDF Items
| ID | Name | Unit | Type | Direction |
|---|---|---|---|---|
| 0 | Car state | 65= A (no car), 66= B (car connected), 67= C (charging), 68= D (charging with ventilation), 69= E (error), 70= F (communication error) | int | IN |
| 1 | Voltage L1 | V | real | IN |
| 2 | Voltage L2 | V | real | IN |
| 3 | Voltage L3 | V | real | IN |
| 4 | Ampere L1 | A | real | IN |
| 5 | Ampere L2 | A | real | IN |
| 6 | Ampere L3 | A | real | IN |
| 7 | Power L1 | kW | real | IN |
| 8 | Power L2 | kW | real | IN |
| 9 | Power L3 | kW | real | IN |
| 10 | Power Total | kW | real | IN |
| 11 | Energy Total | Wh | real | IN |
| 12 | Power unit | kW | string | IN |
| 13 | Energy unit | Wh | string | IN |
| 14 | Current Set | A | real | OUT |
| 15 | Phase set | int | OUT | |
| 16 | Phases | int | IN | |
| 17 | Phases available | int | IN | |
| 20 | Phases Set supported | int | IN | |
| 200 | Quality | int | IN | |
| 201 | Timestamp | datetime | IN | |
| 204 | Info | string | IN | |
| 230 | Debug | int | OUT |
Note
Last Commit: a143a2e8 | 2026-04-13 12:54:24
*2026-04-23 12:31:38 (hw) ******************************
Last Commit: 69568f9e | 2026-04-21 13:52:31
*2026-04-24 06:51:07 (hw) ******************************
Last Commit: 9ace2d31 | 2026-04-24 06:15:35
*2026-04-28 09:48:47 (hw) ******************************
Last Commit: d8f063ee | 2026-04-28 09:46:00
*2026-05-08 17:46:37 (hw) ******************************
Last Commit: ba1780c9 | 2026-05-07 12:41:14
*2026-06-16 07:22:07 (do) ******************************
Last Commit: f5d12c7d | 2026-06-12 08:31:35